No of Towers : 4 Towers per Set External Service Platform with Ladder suitable for4 Towers per set Level Control – 3 Probe Electronic Water Level Control Package suitable for 4 Towers per set Sump Sweeper Piping with High Flow Educator suitable for 4 Towers per set
OPTIMA air curtain is ideal for most of the commercial entrances up to 2,8 meters high. OPTIMA is a small and compact air curtain of elegant and friendly design with rounded shape and edges. Its external casing is customizable in any RAL color to adapt to the internal aesthetics of any premises. Air curtain OPTIMA includes a wall mounted regulation system with remote control. Air curtain Optima Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. Anodized aluminum outlet vanes, airfoil shaped. Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. “P” type with water heated coil. “E” type with electrical shielded elements, two stages with integrated regulation. “A” type without heating, air only. Includes Plug &Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…)
D 100 BAC MS/TP ONICON D-100-BAC Display BACnet MS/TP compatible LCD display of flow rate and total, present value for analog inputs and present value for optional auxiliary pulse total Factory programming with certificate 24, 120 or 240 VAC power w/ internal power supply for flow meter Output Signals: BACnet MS/TP serial network card provides flow rate and total, flow direction, auxiliary analog inputs present value and optional auxiliary input pulse total ONICON F-1200-10 Dual Turbine Insertion Flow Meter NIST traceable wet calibration with certificate Analog outputs: 4-20 mA & 0-10 VDC, or 0-5 VDC (non-isolated, common ground) INSTL1- Standard Installation Hardware for welded steel pipe For installation during new construction or during scheduled system shutdown; includes 1" isolation valve, close nipple and weld-on fitting.
SYSTEM 20 BACnet MS/TP System 20 BTU meter -BACnet BACnet MS/TP with NEMA 12 K enclosure, 24V AC/DC power supply, RS485, single isolated analog output, three (3) aux. pulse inputs and matched pair of current (mA) based temperature sensors, 32°F to 200°F ONICON F-1100-00 Single Turbine Insertion Flow Meter NIST traceable wet calibration with certificate Calibrated frequency output: 0-15 VDC for use with ONICON BTU meter or display module INSTL1- Standard Installation Hardware for welded steel pipe For installation during new construction or during scheduled system shutdown; includes 1" isolation valve, close nipple and weld-on fitting.
SYSTEM 20 BACnet MS/TP System 20 BTU meter -BACnet BACnet MS/TP with NEMA 12 K enclosure, 24V AC/DC power supply, RS485, single isolated analog output, three (3) aux. pulse inputs and matched pair of current (mA) based temperature sensors, 32°F to 200°F ONICON F-1200-00 Dual Turbine Insertion Flow Meter NIST traceable wet calibration with certificate Calibrated frequency output: 0-15 VDC for use with ONICON BTU meter or display module INSTL1- Standard Installation Hardware for welded steel pipe For installation during new construction or during scheduled system shutdown; includes 1" isolation valve, close nipple and weld-on fitting.
D 100 BAC MS/TP ONICON D-100-BAC Display BACnet MS/TP compatible LCD display of flow rate and total, present value for analog inputs and present value for optional auxiliary pulse total Factory programming with certificate 24, 120 or 240 VAC power w/ internal power supply for flow meter Output Signals: BACnet MS/TP serial network card provides flow rate and total, flow direction, auxiliary analog inputs present value and optional auxiliary input pulse total ONICON F-3500-11 Insertion Electromagnetic Flow Meter NIST traceable wet calibration with certificate 316 stainless steel wetted metal components Output signals provided: Analog output for flow rate; 4 20mA or 0-10V or 0-5V Scalable dry contact pulse output for totalization Calibrated frequency output: 0 15 VDC for use with ONICON BTU meter or display module Suitable for 32mm through 1800mm diameter pipe NEMA4 aluminum electronics housing. INSTL1- Standard Installation Hardware for welded steel pipe For installation during new construction or during scheduled system shutdown; includes 1" isolation valve, close nipple and weld-on fitting.